3 resultados para CARDIAC-SURGERY

em Aston University Research Archive


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Central venous catheters have become an integral part of patient management however they are associated with many complications including infection. Despite efforts being made to reduce the incidence of such infect ions the problem continues to increase and has resource implications for the Health Service. Studies relating to the source of microorganisms causing CVC-associated infection, the cost of such infections and the efficacy of an antimicrobial catheter have been undertaken. Thirty patients who required a CVC as part of their medical management and underwent cardiac surgery had the distal tips of their catheters sampled whilst in situ. Sampling took place within 1 h of catheter placement. Bacteria were isolated from 16% of the catheter distal tips sampled in situ. The guidewires used to insert the devices were also contaminated (50%). When CVC were inserted via a protective sheath, avoiding contact with the skin. the incidence of microbial contamination was reduced. These findings suggest that despite rigorous skin disinfection and strict aseptic technique, viable microorganisms are impacted onto the distal tip of CVC during the insertion procedure. Needleless intravascular access devices have been introduced in order to reduce the incidence of need1estick injury. However, it was unclear whether such connectors would act as a portal of entry for microorganisms to CVC. The efficacy of these devices was investigated. Within the controlled laboratory environment it was demonstrated that needleless devices, when challenged with microorganisms, did not allow the passage of microbes when flu id was injected. This therefore suggested that the devices should not increase the risk of catheter colonisation. When used in clinical practice however microbial contamination of the needleless connectors was 55 % in comparison to the routinely used luer connectors (23%). The cost of infections associated with CVC was determined. Twenty patients catheterised with a CVC designed for long term use who were admitted to hospital with a presumptive diagnosis of catheter-related infection were studied. The treatment given specifically for this infection was costed. The mean cost of such an infection was £ 1781.81. Throughout the UK this may amount to £1.565.906 per annum. The cost of infections associated with CVC designed for short term use was estimated to be between 5 and 7 million pounds per annum in the UK. In an attempt to reduce both the incidence and cost of catheter- related infection antimicrobial CVC have been developed. The efficacy of a novel polyurethane CVC impregnated on both the internal and external catheter surface with the quaternary ammonium compound benzalkonium chloride was investigated. Eighty eight patients received an antimicrobial catheter and 78 patients a conventional polyurethane CVC. The anti-microbial CVC resulted in a reduction in microbial colonisation of the external and internal polymer surfaces as compared to the control device. The observed reduction in microbial colonisation with the anti-microbial CVC may decrease the likelihood of subsequent infection offering a useful approach to the prevention of catheter-related infections.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The microbial contamination rate of luers of central venous catheters (CVCs) with either PosiFlow® needleless connectors or standard caps attached was investigated. The efficacy of 70% (v/v) isopropyl alcohol, 0.5% (w/v) chlorhexidine in gluconate 70% (v/v) isopropyl alcohol and 10% (w/v) aqueous povidone-iodine to disinfect the intravenous connections was also assessed. Seventy-seven patients undergoing cardiac surgery who required a CVC as part of their clinical management were randomly allocated either needleless connectors or standard caps. Patients were also designated to receive chlorhexidine/alcohol, isopropyl alcohol or povidone-iodine for pre-CVC insertion skin preparation and disinfection of the connections. After 72 h in situ the microbial contamination rate of 580 luers, 306 with standard caps and 274 with needleless connectors attached, was determined. The microbial contamination rate of the external compression seals of 274 needleless connectors was also assessed to compare the efficacy of the three disinfectants. The internal surfaces of 55 out of 306 (18%) luers with standard caps were contaminated with micro-organisms, whilst only 18 out of 274 (6.6%) luers with needleless connectors were contaminated (P<0.0001). Of those needleless connectors disinfected with isopropyl alcohol, 69.2% were externally contaminated with micro-organisms compared with 30.8% disinfected with chlorhexidine/alcohol (P<0.0001) and 41.6% with povidone-iodine (P<0.0001). These results suggest that the use of needleless connectors may reduce the microbial contamination rate of CVC luers compared with the standard cap. Furthermore, disinfection of needleless connectors with either chlorhexidine/alcohol or povidone-iodine significantly reduced external microbial contamination. Both these strategies may reduce the risk of catheter-related infections acquired via the intraluminal route. © 2003 The Hospital Infection Society. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: To determine the sensitivity and specificity of a novel ELISA for the serodiagnosis of surgical site infection (SSI) due to staphylococci following median sternotomy. Methods: Twelve patients with a superficial sternal SSI and 19 with a deep sternal SSI due to Staphylococcus aureus were compared with 37 control patients who also underwent median sternotomy for cardiac surgery but exhibited no microbiological or clinical symptoms of infection. A further five patients with sternal SSI due to coagulase-negative (CoNS) staphylococci were studied. An ELISA incorporating a recently recognised exocellular short chain form of lipoteichoic acid (lipid S) recovered from CoNS, was used to determine serum levels of anti-lipid S IgG in all patient groups. Results: Serum anti-lipid S IgG titres of patients with sternal SSI due to S. aureus were significantly higher than the control patients (P<0.0001). In addition, patients with deep sternal SSI had significantly higher serum anti-lipid S IgG titres than patients with superficial sternal SSI (P=0.03). Serum anti-lipid S IgG titres of patients with sternal SSI due to CoNS were significantly higher than the control patients (P=0.001). Conclusion: The lipid S ELISA may facilitate the diagnosis of sternal SSI due to S. aureus and could also be of value with infection due to CoNS. © 2005 Published by Elsevier Ltd. on behalf of The Bristish Infection Society.